Xref: utzoo rec.audio:14277 sci.electronics:7187 Path: utzoo!attcan!utgpu!jarvis.csri.toronto.edu!mailrus!cornell!uw-beaver!fluke!strong From: strong@tc.fluke.COM (Norm Strong) Newsgroups: rec.audio,sci.electronics Subject: Re: Cassette Bias Trim Message-ID: <10032@fluke.COM> Date: 1 Aug 89 17:15:08 GMT References: <5482@tekigm2.MEN.TEK.COM> <107@w2xo.UUCP> Sender: news@tc.fluke.COM Distribution: usa Organization: John Fluke Mfg. Co., Inc., Everett, WA Lines: 14 In article <107@w2xo.UUCP> durham@w2xo.UUCP (Jim Durham) writes: [ lots deleted] } (3c). If you are setting up for 70mv p/p, you would get only .707 times } the value rms. However, it sounds like you are *way* down. You may } have a problem. Low gain and rising response vs frequence usually } spells dried-out electrolytic coupling capacitor somewhere. Is this } a new unit? Correction: 70 mv p/p is 28mv rms. You're off by a factor of 2. -- Norm (strong@tc.fluke.com)