Path: utzoo!utgpu!utstat!jarvis.csri.toronto.edu!mailrus!uwm.edu!cs.utexas.edu!uunet!ncis.tis.llnl.gov!lance.tis.llnl.gov!carlson From: carlson@lance.tis.llnl.gov (John Carlson) Newsgroups: comp.windows.x Subject: 'd' and 'i' in R3 HP widgets (was: HP widgets, Tek 88k) Keywords: XHp,XHp X11News Message-ID: <588@ncis.tis.llnl.gov> Date: 31 Oct 89 05:43:55 GMT References: <2556@monarch.oakhill.UUCP> Sender: news@ncis.tis.llnl.gov Organization: University of California, Berkeley Lines: 13 In article <2556@monarch.oakhill.UUCP> razdan@monarch.UUCP (Anshuman Razdan) writes: >I am trying to use the XHp widgets( with patches applied for X11R3) on X11/NeWS >server on a SUN 3/470. The problem is actually with the textwidget(HPtextwidget >). >It does not faithfully reproduce the keyboard input in to the widget. For >example the char "d" is returned as blank and char "i" performs the equivalence >of a RETURN or ENTER. This did not happen when I used the same widget under R2. I posted a patch to this a while ago. I assume that a later distribution fixed the bug, since my patches were removed from expo. John Carlson carlson@tis.llnl.gov