Path: utzoo!attcan!uunet!lll-winken!uwm.edu!zaphod.mps.ohio-state.edu!usc!ucsd!network.ucsd.edu!hp-sdd!apollo!dawson From: dawson@apollo.HP.COM (Keith Dawson) Newsgroups: comp.sys.apollo Subject: Re: DM and logout Message-ID: <4977230c.20b6d@apollo.HP.COM> Date: 28 Mar 90 15:10:00 GMT References: <22581@watdragon.waterloo.edu> Sender: root@apollo.HP.COM Reply-To: dawson@apollo.HP.COM (Keith Dawson) Organization: Hewlett-Packard Company, Apollo Division; Chelmsford, MA Lines: 27 In article <22581@watdragon.waterloo.edu> dvadura@watdragon.waterloo.edu (Dennis Vadura) writes: >Ok, I've RTFM'ed the manual until I am blue in the face, but no luck in ... >So, Is there some way to do this? I can get the pid of the Xapollo process >and send it the HUP if I can run a script prior to loging out. Does the >DM look for the equivalent of a .logout file somewhere, when you logout? From /sys/help/lo: You can execute a DM command script automatically at logout. The logout script must be in a file named `node_data/startup_logout.type, where type is one of the standard display type extensions used for startup filenames (for example, 19l, color, none, and so on). Note that you cannot start up new processes with cp, cps, or cpo from this script, because the DM is in the process of shutting down all existing processes, unless you specify the -w option with cps or cpd. Should'a' RTFH'ed! :^} -->Keith ____________________________________________________________ My opinions Keith Dawson Hewlett Packard Co. 508-256-0176 x5739 are my own. Graphics Technology Division / East 300 Apollo Dr. (CHR.03.DE) Chelmsford, MA 01824 USA My convictions Internet: dawson@apollo.hp.com are not for UUCP: {mit-eddie,yale,uw-beaver}!apollo!dawson public display.