Path: utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!uunet!cbmvax!mks From: mks@cbmvax.commodore.com (Michael Sinz - CATS) Newsgroups: comp.sys.amiga.tech Subject: Re: Multiple Amigas on a SCSI Bus. Message-ID: <10710@cbmvax.commodore.com> Date: 9 Apr 90 13:49:11 GMT References: <1356@lpami.wimsey.bc.ca> Reply-To: mks@cbmvax (Michael Sinz - CATS) Organization: Commodore, West Chester, PA Lines: 22 In article <1356@lpami.wimsey.bc.ca> lphillips@lpami.wimsey.bc.ca (Larry Phillips) writes: > [ lots-o-stuff deleted ] >Disconnect/reconnect... I noticed a posting from Dave Haynie that mentioned the >2091 disconnecting between the command and data phases in case something else >needs to use the bus. Is this 'generic' disconnect/reconnect capability? It >would be real nice if it is, so I could keep the tape streaming without having >to go to a separate tape controller. If it has this capability, can it be >turned on/off on a physical device basis for those devices that do not support >the capability? Yes, the Deselect/reselect is available on a device (SCSI-ID) by device level. It is stored in the 2091 HDToolBox under the drive type definitions. Yes, this would make streaming possible. /----------------------------------------------------------------------\ | /// Michael Sinz -- CATS/Amiga Software Engineer | | /// PHONE 215-431-9422 UUCP ( uunet | rutgers ) !cbmvax!mks | | /// | |\\\/// "I don't think so," said Ren'e Descartes. | | \XX/ Just then, he vanished. | \----------------------------------------------------------------------/