Path: utzoo!attcan!uunet!samsung!dali!uakari.primate.wisc.edu!zaphod.mps.ohio-state.edu!sol.ctr.columbia.edu!emory!hubcap!mephisto!prism!cc100aa From: cc100aa@prism.gatech.EDU (Ray Spalding) Newsgroups: comp.sys.cdc Subject: Re: B1 and other fun stuff Message-ID: <7647@hydra.gatech.EDU> Date: 3 Apr 90 19:13:33 GMT References: <5475@scolex.sco.COM> <8939@boring.cwi.nl> Reply-To: cc100aa@prism.gatech.EDU (Ray Spalding) Organization: Georgia Institute of Technology Lines: 22 In article <8939@boring.cwi.nl> dik@cwi.nl (Dik T. Winter) writes: > Better is the following which requires >only the load-cycles for each step through the load: > SA1 INITIAL >+ BX6 X1-X0 > SA1 A1+B1 > NZ X6,* You're right, and this functional-unit-overlapping sequence is in fact what Mansfield used in COMCMTM/EQS. >Oh yes, happy memories. Agreed. -- Ray Spalding, Office of Computing Services Georgia Institute of Technology, Atlanta Georgia, 30332-0275 uucp: ...!{allegra,amd,hplabs,ut-ngp}!gatech!prism!cc100aa Internet: cc100aa@prism.gatech.edu