Path: utzoo!attcan!utgpu!news-server.csri.toronto.edu!clyde.concordia.ca!uunet!hsi!essnj1!smitty From: smitty@essnj1.UUCP (Hibbard T. Smith JR) Newsgroups: comp.dcom.modems Subject: Telebit T1000 problem. Keywords: Telebit, T1000 Message-ID: <728@essnj1.UUCP> Date: 26 May 90 04:21:07 GMT Organization: ESSNJAY Systems Inc., Bethany, CT, USA Lines: 28 I've been using a Telebit T1000 for a year now, and I like it a lot. My system is a 386 25Mhz running ISC 2.0.2 with the X5 upgrade installed. I have the Dialers and Devices files configured to lock the T1000 to the speed of the Systems file entry for the particular system being called. The T1000 is configured to reset to the stored profile when DTR drops at the end of the call. The stored profile allows the modem answer speed to float in response to incoming calls. The problem is that after an outbound call, the modem will not float to the speed of an incoming call. It only offers the speed at which the preceeding (outbound) call was made. Apparently the speed lock is remaining in effect, and the stored profile is not being obeyed. I've checked with a scope, and the system drops DTR for a couple of seconds. If I drop DTR manually, or power down and up the modem, the "float" works properly. Any help I can get with this would be deeply appreciated. It's causing some incoming calls to be answered (ie paid for), but not connected. This is a source of irritation for some of my users. Please email responses, unless you feel it's of general interest. I'll follow this group watching for followups. Thanks in advance for any help. -- Smitty ------------------------------------------- Hibbard T. Smith JR ESSNJAY Systems Inc. uunet!hsi!essnj1!smitty