Path: utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!tut.cis.ohio-state.edu!uc!shamash!rrr From: rrr@svl.cdc.com (rich ragan) Newsgroups: comp.sys.cdc Subject: Re: Vector setup time for Cyber 995 Message-ID: <23585@shamash.cdc.com> Date: 19 Jul 90 16:46:25 GMT References: <1990Jul18.131615.1491@nat.vu.nl> Sender: news@shamash.cdc.com Lines: 31 Hans Spoelder requested vector setup times for Cyber 995. The following are the vector setup times for the 995E: N is the vector length (max of 512). Times are given as clock units which is 16 nsec for the 995. Thus, ADDXV takes 52 clocks to setup and produces a result per clock after that. ADDXV 52+N Integer Add SUBXV 52+N Integer Subtract CMPxxV 53+N Integer compares (where xx= EQ, LT, GE, NE) SHFV 55+N Shift IORV 52+N Inclusive OR XORV 52+N Exclusive OR ANDV 52+N And CNIFV 53+N Convert Integer to Float CNFIV 53+N Convert Float to Integer ADDFV 56+N Floating Add SUBFV 56+N Floating Subtract MULFV 56+N Floating Multiply DIVFV 80+7N Floating Divide SUMFV 82+N Floating Sum Reduction MRGV 51+N Merge vectors GTHV 73+N Periodic gather SCTV 81+N Periodic scatter -- Richard R. Ragan (408) 496-4340 Control Data Corp., Silicon Valley Operations -- Richard R. Ragan (408) 496-4340 Control Data Corp., Silicon Valley Operations