Path: utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!swrinde!zaphod.mps.ohio-state.edu!sol.ctr.columbia.edu!emory!hubcap!ncrcae!sauron!wescott From: wescott@Columbia.NCR.COM (Mike Wescott) Newsgroups: comp.sys.ncr Subject: Re: Terminal distribution box Message-ID: <2240@sauron.Columbia.NCR.COM> Date: 24 Jul 90 00:38:27 GMT References: <1631@ssbn.WLK.COM> Sender: news@sauron.Columbia.NCR.COM Reply-To: wescott@micky.Columbia.NCR.COM (Mike Wescott) Distribution: na Organization: E&M-Columbia, NCR Corp, W Columbia, SC Lines: 66 In article <1631@ssbn.WLK.COM> bill@ssbn.WLK.COM (Bill Kennedy) writes: > I'm somewhat of a neophyte when it comes to the Tower series, and > very new to this newsgroup, so forgive me if this has been hashed > over dozens of times. The newsgroup is too new for anything to have been hashed over a dozen times. > I have a 32/400 with two hpsio cards. The first one comes out to > eight DB-15's but the second has a pair of DB-37's(?) for tty08 > to tty15. [...] > Does anyone have the pinouts for those connectors? Check out the wiring diagrams in the Hardware Service Manual. It's called the "NCR TOWER 3400 Series Servicing/Installation Guide" with a document number D2-0111-A. DB37 SIGNAL DB15 1 TD 1 2 GND 11 3 RTS 2 4 CTS 10 Channel 0 5 CD 12 20 DTR 4 21 DSR 3 22 RD 9 23 NC 6 TD 1 7 GND 11 8 RTS 2 9 CTS 10 Channel 1 24 CD 12 26 DTR 4 25 DSR 3 27 RD 9 28 NC 11 TD 1 12 GND 11 31 RTS 2 13 CTS 10 Channel 2 10 CD 12 29 DTR 4 30 DSR 3 32 RD 9 33 NC 18 TD 1 17 GND 11 16 RTS 2 15 CTS 10 Channel 3 14 CD 12 35 DTR 4 36 DSR 3 34 RD 9 37 REVCH 13 19 LL 5 -- -Mike Wescott mike.wescott@ncrcae.Columbia.NCR.COM