Path: utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!asuvax!ncar!boulder!daemon From: JOHN@heap.cisco.com (John Wright) Newsgroups: comp.dcom.sys.cisco Subject: Re: Power consumption Message-ID: <26316@boulder.Colorado.EDU> Date: 15 Sep 90 00:25:50 GMT Sender: daemon@boulder.Colorado.EDU Lines: 29 I must apologize, sometimes I find it faster to dig up answers to questions that I don't remember the answers to off the mail archives when I am working away from appropriate manuals. I did that today for the AGS+ power question and I forwarded a message that had a typo in it, that particular message had been corrected in a later message which I did not see in the archive file. Sorry for the confusion, and many thanks to the dozens of people who have sent me sometimes humorous replies. ;-) Here is this question answered by the engineer that does the specifications/certifications for the power supplies we use: --- The actual power ratings for the AGS+ product are 7 amps @ 110 VAC and 3.5 Amps @ 220 VAC. These are listed in the new installation guide. For UPS information, the AGS+ power supply will hold output for approximately 20 msec. after power loss at nominal line voltage (derate to 6 msec. at low line - 95 VAC-). ------- The 'new installation' guide mentioned is a draft document version not yet available. Again, sorry for the confusion and extra net traffic this has caused. John Wright Customer Engineering cisco Systems, Inc. -------