Path: utzoo!censor!geac!torsqnt!news-server.csri.toronto.edu!cs.utexas.edu!usc!srhqla!demott!kdq From: kdq@demott.COM (Kevin D. Quitt) Newsgroups: comp.unix.admin Subject: Re: How to disconnect idle dialup users? Message-ID: <1033@demott.COM> Date: 27 Nov 90 06:00:55 GMT References: <1990Nov27.015820.18884@cubmol.bio.columbia.edu> Reply-To: kdq@demott.COM (Kevin D. Quitt) Organization: DeMott Electronics Co., Van Nuys CA Lines: 16 In article <1990Nov27.015820.18884@cubmol.bio.columbia.edu> ping@cubmol.bio.columbia.edu (Shiping Zhang) writes: >Some users dialup onto the machine and hang on for hours doing nothing. >I tried to disconnect the hookup using the kill command but failed. If you've a Telebit modem, register S41 can be set in tenths of hours, from 0 (disabled) to 255. When the timer expires, the modem hangs up the line. -- _ Kevin D. Quitt demott!kdq kdq@demott.com DeMott Electronics Co. 14707 Keswick St. Van Nuys, CA 91405-1266 VOICE (818) 988-4975 FAX (818) 997-1190 MODEM (818) 997-4496 PEP last 96.37% of all statistics are made up.