Newsgroups: comp.sys.apollo Path: utzoo!utgpu!news-server.csri.toronto.edu!helios.physics.utoronto.ca!alchemy.chem.utoronto.ca!system From: system@alchemy.chem.utoronto.ca (System Admin (Mike Peterson)) Subject: Re: 10K power supply problem Message-ID: <1990Dec7.182641.721@alchemy.chem.utoronto.ca> Organization: University of Toronto Chemistry Department References: <9012070028.AA04240@wolf.Uwyo.EDU> Date: Fri, 7 Dec 90 18:26:41 GMT In article <9012070028.AA04240@wolf.Uwyo.EDU> waldram@WOLF.UWYO.EDU writes: >FYI: > DN 10000 owners: > We have experienced some severe power supply shutdown problems >on our 10K. Symptoms are: > 1) System loses main power. > 2) Standby lamp on front pannel lit > 3) Error status 30 (HEX) on EuroCard power supply plugged into > the bottom of the X bus. > >Situation: >A problem has been identified with the DN100X0/DSP100X0 power sys- >tems in both Manufacturing and the Field. The power system shuts down >due to a +5 Volt OV (Over Voltage) failure. > >After having tested different +5 Volt Booster Module configurations, >R&D has concluded that Booster Modules with 1988 Datecodes are the >direct cause of the +5 Volt OV (overvoltage failures). We have had our power supply replaced 4 times in 2 years with exactly this problem - does anyone know what, if any, revision of this board fixes the problem (our board went from Rev 2 to Rev 4 when it was replaced last week - are we now "protected")? -- Mike Peterson, System Administrator, U/Toronto Department of Chemistry E-mail: system@alchemy.chem.utoronto.ca Tel: (416) 978-7094 Fax: (416) 978-8775