Path: utzoo!mnetor!tmsoft!torsqnt!news-server.csri.toronto.edu!cs.utexas.edu!evax!utacfd!merch!rwsys!jim From: jim@rwsys.lonestar.org (James Wyatt KA5VJL .) Newsgroups: comp.dcom.modems Subject: Re: connect problems with T2500 Summary: there's an undocumented register to fix this Keywords: Telebit T2500 T1000 TrailBlazer Plus PEP connect problems S99 Message-ID: <8791@rwsys.lonestar.org> Date: 20 Dec 90 17:18:47 GMT References: <1990Dec19.044634.26743@sopwith> <114896@uunet.UU.NET> Reply-To: jim@rwsys.lonestar.org (James Wyatt KA5VJL) Organization: R/W Systems, Richland Hills, Texas, 76118-5849 (817) 595-0571 Lines: 11 In article <114896@uunet.UU.NET> ebersman@uunet.UU.NET (Paul Ebersman) writes: >Starting with ROM Revision 6.0 for T2500's, a v.25 guard tone was put >before PEP in the carrier tone sequence and other changes were made. >This can cause earlier ROM Revisions of T2500's and TB+'s to be unable This is correct. As usual, Telebit has prepared for this. Setting s99 to 1 will alter the v.25 guard tone behaviour, permitting connection w/ T1000s. The T2500 really is a fantastic box - I wish my Supra 2400 worked as well. ---- James Wyatt (KA5VJL) - Standard disclaimer applies... (H)817-595-0571 {letni.lonestar.org,merch.tandy.com}!rwsys.lonestar.org!jim (W)817-390-2864