Path: utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!usc!apple!bbn.com!drilex!wrglex!j_prigot From: j_prigot@wrglex.uucp Newsgroups: comp.sys.dec Subject: Re: Vax750 PROBLEMS!! Message-ID: <111.27786b76@wrglex.uucp> Date: 26 Dec 90 14:20:54 GMT References: <1990Dec18.170238.6551@uunet!konkord> <1990Dec19.171315.903@spcvxb.spc.edu> Organization: W.R. Grace & Co., Lexington, MA Lines: 19 In article <1990Dec19.171315.903@spcvxb.spc.edu>, terry@spcvxb.spc.edu (Terry Kennedy, Operations Mgr) writes: > In article <1990Dec18.170238.6551@uunet!konkord>, jar@konkord.uucp (John Roberts) writes: >> ANY HELP would be great! I've been working on this >> problem for 2 weeks now, and NOTHING!!! ARG!!! > > If you inherited this VAX from somewhere where it was on a DEC Field Service > contract, FS has removed the Remote Diagnostic Module from slot 6 (I think), > leaving the TU58 and the console disconnected. Look at the cover on the back- > plane - it should have a sticker showing where to move the connectors to in > order to work w/o the RDM installed. It also shows the baud rate select jum- > pers for the console port. > And in case it doesn't, my "VAX Maintenance Handbook (VAX-11/750)" says to move the following cables from the right side of slot 6 to the left side: Front panel cable (row A), TU58 cable (row B), console cable (row C). -- Jonathan M. Prigot j_prigot@wrglex or ...!drilex!wrglex!j_prigot