Path: utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!rutgers!mcdchg!heiby From: heiby@mcdchg.chg.mcd.mot.com (Ron Heiby) Newsgroups: comp.sys.m88k Subject: Re: Request for help: Location Monitors on the Motorola MVME188 board Message-ID: <54451@mcdchg.chg.mcd.mot.com> Date: 15 Jan 91 00:27:23 GMT References: <14423@june.cs.washington.edu> <54437@mcdchg.chg.mcd.mot.com> Organization: Motorola Computer Group, Schaumburg, IL Lines: 9 I think Michael didn't mention one thing that some of my 68K customers have run into when using location monitors. That is that the board that is the target of the LM access, the one that is about to enter an interrupt routine, does *NOT* respond to the VMEbus cycle. The board that makes the access to trigger the LM must be prepared for a bus error (BERR) on that cycle. -- Ron Heiby, heiby@chg.mcd.mot.com Moderator: comp.newprod "Give me voice mail or give me drugs!"/"Mandatory Drug Testing? Just Say NO!!!"