Path: utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!uunet!fciva!dag From: dag@fciva.FRANKLIN.COM (Daniel A. Graifer) Newsgroups: comp.dcom.modems Subject: Trouble w/ TB+ calling T2500 in PEP/UUCP mode Message-ID: <577@fciva.FRANKLIN.COM> Date: 15 Jan 91 22:54:50 GMT Reply-To: dag@fciva.UUCP (Daniel A. Graifer) Distribution: na Organization: Coastal Capital Funding Corp., McLean, Va. Lines: 19 We have several Telebit Trailblazer Plus modems and one T2500 (v7.00) modem on various machines. In uucp mode (S111=30) at 19200bps I can easily call between the TB+s and from the T2500 to them. When I try to call from the TB+s to the T2500, the modems never finish handshaking, the T2500 repeats the last part of the sequence (short-short-LONG-pause(2) whitenoise(3) pause over and over). I've set up S7 to 60 so the calling modem doesn't time out, and added "\r\d\d\d\d\c" to the Dialer sequence so uucico doesn't timeout waiting for the connect. Oh, I have the register set to present PEP at the end (S92=1). Anybody have any ideas? How about a tech support number at Telebit? Thanks in advance. Dan -- Daniel A. Graifer Coastal Capital Funding Corp. Sr. Vice President, Financial Systems 7900 Westpark Dr. Suite A-130 (703)821-3244 McLean, VA 22102 uunet!fciva!dag fciva.FRANKCAP.COM!dag@uunet.uu.net