Path: utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!wuarchive!sdd.hp.com!uakari.primate.wisc.edu!dali.cs.montana.edu!ogicse!pdxgate!parsely!percy!qiclab!techbook!kenh From: kenh@techbook.com (Ken Haynes) Newsgroups: comp.sys.novell Subject: Re: IPX upgrade for Windows3.0 Keywords: IPX Window3.0 Message-ID: <1991Feb13.142300.29275@techbook.com> Date: 13 Feb 91 14:23:00 GMT References: <21364@versatc.versatec.COM> Organization: TECHbooks of Beaverton Oregon - Public Access Unix Lines: 26 In article <21364@versatc.versatec.COM> dan@versatc.versatec.COM (Dan Ching) writes: > > >I've installed Windows3.0 on my Novell file server (Compaq Deskpro386) >and I want to run Windows3.0 in 386 Enhanced mode. During the Windows >installation I was notified that my network shell was invalid and that >I need to upgrade the network shell. I've been able to bring Windows >up in REAL mode but not in 386 Enhanced mode. > >Can I run Windows in 386 Enhanced mode if I have Advanced NetWare 286 >ND V2.15 on the non-dedicated file server connected to a 386 clone >running MS-DOS v4.01? I am current using Advanced NetWare v2.15 rev A >- Workstation Shell for DOS v4.X as my network shell. Absolutely NOT. Non dedicated NW pops back and forth from protected to real mode. Windows 3.0 requires control of the CPU for protected mode operation. The two programs will be fighting over control of protected mode. You can run windows from a workstation not used as the file server. You will need the 3.01 shells. They are up to REV. E. The files are available from NETWIRE. -- ****************************************************************************** Ken Haynes, Certified Netware Engineer Technical Support Product Mgr. 900 Support