Path: utzoo!utgpu!news-server.csri.toronto.edu!bonnie.concordia.ca!uunet!maverick.ksu.ksu.edu!iowasp.physics.uiowa.edu!syswtr From: syswtr@iowasp.physics.uiowa.edu Newsgroups: comp.os.cpm Subject: Re: Motor on and Drive Select Message-ID: <1991Feb19.133929.568@iowasp.physics.uiowa.edu> Date: 19 Feb 91 19:39:28 GMT References: Distribution: comp Organization: Department of Physics and Astronomy, University of Iowa Lines: 9 Most of the floppy varieties I have seen are jumperable to allow the MOTOR-ON signal to control the motor without also using DS. That is, MOTOR-ON turns ALL motors on. This should eliminate any problems with motor spin-up delays when moving from drive-to-drive. In some of the older 8" systems we have about, I set the 8" drives to all load the head at the same time (whenever head-load was asserted) to eliminate head settling delay when moving from drive to drive. Willy