Path: utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!usc!wuarchive!rex!mandel@vax.anes.tulane.edu From: mandel@vax.anes.tulane.edu (Jeff E Mandel MD MS) Newsgroups: comp.sys.dec Subject: Re: Trailblazer setup - help needed! Message-ID: <6279@rex.cs.tulane.edu> Date: 22 Feb 91 23:29:04 GMT References: <400@motto.UUCP> Sender: news@rex.cs.tulane.edu Organization: Tulane University School of Medicine Lines: 33 In article <400@motto.UUCP> murray@motto.UUCP (Murray S. Kucherawy) writes: >I just got a trailblazer for our MicroVAX II ("motto"), and I'm trying >to switch from our Hayes-compatible 1200 baud modem to this modem. > >But I can't get my trailblazer to work. It will talk in all the baud rates >I want it to if I hook up a terminal to it and try it... autobauding >is fine. It also answers and connects properly when I dial manually, no >matter what baud rate. > >The problem lies in getting our uVAX to talk to it properly. We're running >Ultrix V2.0-1, and it's coming off a port that is was configured at 1200 >baud, and is now configured for 9600 baud. > I run VMS, and had some problems until I got my settings right: S00=001 S01=000 S02=043 S03=013 S04=010 S05=008 S06=002 S07=080 S08=002 S09=006 S10=007 S11=050 S12=000 S45=255 S47=004 S48=000 S49=000 S50=000 S51=005 S52=001 S53=002 S54=003 S55=003 S56=017 S57=019 S58=000 S59=000 S60=000 S61=020 S62=002 S63=001 S64=001 S65=000 S66=001 S67=001 S68=255 S90=000 S91=000 S92=000 S95=000 S100=000 S101=000 S102=000 S104=000 S110=001 S111=255 S112=001 S120=012 S121=000 Note that this is for 19200. Good luck with the Ultrix. Jeff E Mandel MD MS Asst Professor of Anesthesiology Tulane University School of Medicine New Orleans, LA Brought to you by Super Global Mega Corp .com