Path: utzoo!utgpu!news-server.csri.toronto.edu!rpi!usc!sdd.hp.com!spool.mu.edu!munnari.oz.au!mel.dit.csiro.au!latcs1!wcc!tom From: tom@wcc.oz.au (Tom Evans) Newsgroups: comp.protocols.appletalk Subject: Re: Problem with Webster Multigate Keywords: webster multigate lights exception fault Message-ID: <1653@wcc.oz.au> Date: 18 Mar 91 00:37:02 GMT References: <9135@castle.ed.ac.uk> Organization: Webster Computer Corp, Melbourne, Australia Lines: 35 In article <9135@castle.ed.ac.uk>, ercm20@castle.ed.ac.uk (Sam Wilson) writes: > I've just been configuring my second Multigate. The first one came up > with no problems. The second is temperamental. > > ... The one occasion I happen to > have had MGTalk running when this happens I saw a repeated error > message saying: > > "Exception 2 at PC = 0x6F14 to ipl=7 from ipl=7 > Supervisor data word read access of addr 0x178C3A. ssw=1105" 0x178C3A is a legitimate address up near the top of the 1/2Mb of DRAM. Exception 2 is a 68K Bus Error. This is likely to be a Memory Parity Error. It may also be that the MultiPort Gateway was damaged in transit on the way to Scotland, and that is causing it. MGTalk (Application that runs on a Mac connected to the MPG's Console port) is just a terminal emulator. Leave it running - connected to the MPG and see what other error reports (if any) you get. I've sent more details (on debugging and theory of operation) by separate mail to Sam Wilson. ======================== Tom Evans tom@wcc.oz.au Webster Computer Corp P/L, 1270 Ferntree Gully Rd Scoresby, Melbourne 3179 Victoria, Australia 61-3-764-1100 FAX ...764-1179 A.C.N. 004 818 455 wcc@cup.portal.com 2109 O'Toole Avenue, Suite J SAN JOSE CA 95131 - 1303 CALIFORNIA 1-408-954-8054 FAX 1-408-954-1832 wcc-uk@cup.portal.com Unit 7, Weltech Centre Ridgeway, Welwyn Garden City Herfordshire AL7 2AA LONDON UK. Ph 44-707-336969 Mobile 44-836-725849 FAX 44-707-373378