Path: utzoo!utgpu!news-server.csri.toronto.edu!rpi!usc!cs.utexas.edu!evax!utacfd!merch!cpe!adaptex!adaptx1!neese From: neese@adaptx1.UUCP Newsgroups: comp.periphs.scsi Subject: Re: Two HAs on single SCSI bus Message-ID: <283400092@adaptx1> Date: 1 Apr 91 22:27:07 GMT References: <3474@seachg.uucp> Lines: 17 Nf-ID: #R:seachg.uucp:3474:adaptx1:283400092:000:716 Nf-From: adaptx1.UUCP!neese Apr 1 09:14:00 1991 >I tried to do this with 2 Adaptek 1542a controllers and a Connor >100meg SCSI drive. Wouldn't work. Adaptek was absolutely unresponsive >when I sought help. The A board did not take into account this scenario. The B board should work fine in this environment. Although, if this is the CP3100, there may be other problems. I have had many reports about the CP3100 not coexisting with other devices very well, causing hangups on the SCSI bus. One thing to be aware of,...you must change the ID of one of the adapters. By default they are set to 7. Should set one of them to 6. Roy Neese Adaptec Senior SCSI Applications Engineer UUCP @ neese@adaptex uunet!cs.utexas.edu!utacfd!merch!adaptex!neese