Path: utzoo!utgpu!news-server.csri.toronto.edu!rpi!zaphod.mps.ohio-state.edu!sdd.hp.com!hp-pcd!hpfcso!hppad!lapp From: lapp@hppad.waterloo.hp.com (David Lapp) Newsgroups: comp.sys.hp Subject: Re: looking for help with new X code from hpcvaaz Message-ID: <1050007@hppad.waterloo.hp.com> Date: 11 Apr 91 19:48:45 GMT References: <1991Apr6.221036.16866@bronze.ucs.indiana.edu> Organization: HP Panacom Div Waterloo ON Canada Lines: 22 Well lets see, in order: 1) try just XDMCP = ENABLED Apparently RTFM wouldn't have helped you as the code and the manuals have different things for this. (This from a lab guy trying not to say 'the manuals are wrong' :-). 2) The 700X does not support .Xauthority. At least not in any meaningful way. It does pass MIT-MAGIC-COOKIE as a password but ... well this (surprise surprise) doesn't provide much protetction. The 700X does not support XDM-AUTHORIZATION-1. This is in part due to export restrictions on DES based code. Sorry. Hope that helped. Dave Lapp lapp@waterloo.hp.com Standard Disclaimer etc... i.e. I thought it, I wrote it, not HP.