Path: utzoo!utgpu!news-server.csri.toronto.edu!rpi!zaphod.mps.ohio-state.edu!mips!pacbell.com!ucsd!nosc!baron!baron!pnet07!donm From: donm@pnet07.cts.com (Don Maslin) Newsgroups: comp.os.cpm Subject: Re: Help: Tandon Disk Drive & Xebek controller Message-ID: <1991Apr21.232504.9012@simasd.uucp> Date: 21 Apr 91 23:25:04 GMT Sender: pnet@simasd.uucp (People-NET) Organization: People-Net [pnet07], San Diego, CA Lines: 45 etpkg@levels.sait.edu.au writes: >So, If someone has details of the jumpers of the Tandon drive they would be >much appreciated.... The jumpers and factory settings for the TM 50x drives are as below: Jumper Function Setting Usage W1 Track Fault O Install for excess track fault W2 Test O Install for factory test W3 Disable Limit O Install to disable soft limits W4 Spin Select O Install for spin select W5 Tracks S Install for standard version W6 Motor Type - Install for Type 1.8 motor RTW7 Read Terminator I Close only at end drive of daisy chain data. Closed for radial data. WTW8 Write Terminator I S4W9 Drive Select 4 O Install one of four plugs only S3W10 Drive Select 3 O Plug corresponds to drive addr S2W11 Drive Select 2 O S1W12 Drive Select 1 I 3PW13 Three Disk 503 Close for TM503 only U22 Terminator Pack I Install in end drive of daisy chain. NOTES: O Omit I Install S Close jumper for standard version only 503 Close jumper for TM503 only > [...] The hard disk controller in the ICL is a Xebek Systems >model 104526 (at least thats the only number written on it). The jumper >settings for this would also be good. > Sorry, I can't help you out on that. Perhaps someone else will. - don Keeper of the CP/M System Disk | UUCP: {nosc ucsd crash ncr-sd}!pnet07!donm Archives for the Dino(saur)SIG | ARPA: simasd!pnet07!donm@nosc.mil - San Diego Computer Society - | INET: donm@pnet07.cts.com