Path: utzoo!utgpu!news-server.csri.toronto.edu!rpi!uwm.edu!ux1.cso.uiuc.edu!roundup.crhc.uiuc.edu!pacific.csl.uiuc.edu!steven From: steven@pacific.csl.uiuc.edu (Steven Parkes) Newsgroups: comp.sys.dec Subject: Making a GPX/II grayscale ... Message-ID: <1991Apr29.175820.18394@roundup.crhc.uiuc.edu> Date: 29 Apr 91 17:58:20 GMT Sender: news@roundup.crhc.uiuc.edu Reply-To: steven@pacific.csl.uiuc.edu Organization: Coordinated Science Laboratory, University of Illinois Lines: 8 We have a color Vaxstation II/GPX that we want to turn into a grayscale machine by swapping the VR290 with a VR260/VR262. DEC Direct said that a BC18P is a cable that will allow the attachment of a VR260 to the GPX/II. Well, we have this cable on another MVIII (of some sort), so I tried using it. However, the 260 doesn't sync up correctly when attached to the GPX/II -- this problem happens both under X and in dumb-terminal mode. Does anyone know of any way of getting this to work?