Path: utzoo!utgpu!news-server.csri.toronto.edu!rpi!usc!samsung!uunet!ogicse!plains!overby From: overby@plains.NoDak.edu (Glen Overby) Newsgroups: comp.os.minix Subject: Re: DOS and Minix Partitions Message-ID: <10233@plains.NoDak.edu> Date: 7 May 91 04:36:59 GMT References: <1217@opus.NMSU.Edu> Organization: Tea & Ching labs Lines: 15 In article <1217@opus.NMSU.Edu> kduling@nmsu.edu (Kevin Duling) writes: > I'm trying to run Minix 1.5 on a Tandy 1000 SX (8088 processor) with a 32 Meg >Seagate 138R drive that has a Super Bios II formatter (Copywrite Western You have to enable the AUTO_BIOS option of both xt_wini and xt2_wini (this option should be set in around line 40-something) and the controler should work like a charm (mine does). Your problem comes from the WD controler writing the disk geometry on the primary boot sector, just in front of the partition table. Without AUTO_BIOS set, both wini drivers assume that they should retrieve parameters out of ROM, where there are some conservative parameters for 10MB drives. -- Glen Overby uunet!plains!overby (UUCP) overby@plains (Bitnet)