Xref: utzoo biz.comp.telebit:82 comp.dcom.modems:9891 Newsgroups: biz.comp.telebit,comp.dcom.modems Path: utzoo!utgpu!news-server.csri.toronto.edu!rpi!think.com!zaphod.mps.ohio-state.edu!casbah.acns.nwu.edu!hayes.ims.alaska.edu!floyd From: floyd@ims.alaska.edu (Floyd Davidson) Subject: Re: Can you change the pulse timing on T2500's? Message-ID: <1991May22.014949.14165@ims.alaska.edu> Organization: University of Alaska Institute of Marine Science References: <1991May20.153657.654@shaman.com> <1991May21.044113.1688@osh3.OSHA.GOV> Date: Wed, 22 May 1991 01:49:49 GMT Lines: 25 In article <1991May21.044113.1688@osh3.OSHA.GOV> chip@osh3.OSHA.GOV (Chip Yamasaki) writes: >In <1991May20.153657.654@shaman.com> jiro@shaman.com (Jiro Nakamura) writes: > >>Hiya - >> Quick question: > >> Is it possible to change the speed of the pulse dialing on >>Telebit T2500's? I haven't counted, but it seems like it's about >>15 pps, I'd like to move it up to 20 pps if possible. > >Check the manual, pp 4-32 and 5-38 both list S Register 11 which sets the >Touch tone timing. There the manual says "The S11 register does NOT >affect pulse dialing which IS FIXED at 100 milliseconds per pulse." > >No, you can't change it. Just to add a little to this... Telephone switch systems are also "fixed" at 10 pps, so changing it would most likely cause errors (8-12 pps would probably work, out of that range and the switch will think it isn't dial pulse anymore). Floyd -- Floyd L. Davidson | Alascom, Inc. pays me, |UA Fairbanks Institute of Marine floyd@ims.alaska.edu| but not for opinions. |Science suffers me as a guest.