Path: utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!wuarchive!uunet!mcsun!hp4nl!cbmnlux!ecl014!ronald From: ronald@ecl014.UUCP (Ronald van Eijck) Newsgroups: comp.sys.amiga.datacomm Subject: Re: Worldport 9600 -> TrailBlazer Message-ID: Date: 27 May 91 17:17:07 GMT References: <1991May25.173825.26747@netcom.COM> Organization: R&R Software Lines: 41 In article <1991May25.173825.26747@netcom.COM> gandrews@netcom.COM (Greg Andrews) writes: >> >>I'm trying to make a connection between a Worldport 9600 modem and a >>trailblazer. Without any success sofar. >> >>This is wat happens: >>The wp dials the trailblazer >>the trailblazer gives it's connection sounds >>the trailblazer gives a sound that goes like this beep silence beep silence >>etc. >>When the trailblazer stops this sequence the worldport gives a No carrier >>message. >> >>Any ideas how to solve this? >> > >Yes, make sure the TrailBlazer has its S50 register at the value of 0 >rather than 255. > >Since the TrailBlazer is answering with its high-speed PEP tones first, >you'll probably need to adjust the WorldPort's S7 register to a higher >value like 60 or 90. Also make sure your comm software will wait longer >for the connection. > > | Greg Andrews | UUCP: {apple,amdahl,claris}!netcom!gandrews | Will this change of register S50 have any influence on the performance of trailblazer to trailblazter communication?? The problem is that the trailblazer is a commodore network site and I'm just a customer so I don't think they will change anything if it gives a worse performance for other people Thanx, -- +-------------------------------------------------------------------------+ | Ronald van Eijck {eunet!}hp4nl!cbmnlux!ecl014!ronald | | | | We do the impossible at once for a miracle we need a little more time | +-------------------------------------------------------------------------+