Path: utzoo!utgpu!news-server.csri.toronto.edu!rpi!zaphod.mps.ohio-state.edu!ub!csn!daveh From: daveh@csn.org (Dave Hughes) Newsgroups: comp.unix.sysv386 Subject: dialTBIT and T2500 Puzzle Summary: How to get T2500 on SCO Unix 3.2.2 to talk 19.2 to another T2500 Keywords: dialTBIT T2500 Message-ID: <1991Jun15.181530.21573@csn.org> Date: 15 Jun 91 18:15:30 GMT Organization: Colorado SuperNet Inc. Lines: 66 We are setting up a Telebit T2500 using SCO Unix 3.2.2 and the dialTBIT program that SCO provided with the release. (Which won't even compile on the SCO Unix system unless I comment out the 'nap' lines). We are trying to use the T2500, UUCP link to T2500s at Colorado Supernet (csn.org) running on Suns, for UUCP, netmail, and eventually B-news. We have examined and tried many combinations of Tbit register settings, dialTBIT MDSETUP initialization strings from four different sources (Tbit manual, SCO dialTBIT code, Nutshell, and csn suggested settings but nothing works, and there are a host of contradictions between these documents.) 1. The modem is not locking the speed at 19200 but instead allowing it to drop to 9600. Is there a way to keep the modem from rotating down and connecting except at 19200? I've tried the S51 and S66 settings and they don't seem to do it. 2. When I do get a connect at 9600, in UUCP the Tbit is not passing the information on to the Systems file causing it to never send the login name, password, etc. The Systems file entry works fine at 9600 baud, and has for several months using a Robotics dual standard V32 at our end, and the SCO release dialHA24 with the modem speed in the code simply set to and compiled as dialHA96. So it has to be something with the Tbit and the dialTBIT dialer. Incidentally, I'm calling into Colorado SuperNet so if anybody has a telebit connection with them and was willing to share it would reduce the possibility of them needing something special. Below is a table showing the differences in the settings recommended by csn, sco (dialer program strings), nutshell, and the T2500 manual, and what we last tried to use. All settings not listed are the default T2500 settings. CSN SCO NUTSHELL T2500 What we last tried V0 V1 - V1 V1 E0 E0 E0 E1 E0 X0 X3 - X1 X3 - F1 - F1 F1 Q0 Q4 Q4 Q0 Q4 S7 65 - - 40 S7=40 S10 254 - - 7 S10=30 S48 - 1 - 0 S48=0 S51 254 254 254 255 S51=254 S52 2 2 2 0 S51=2 S54 3 3 3 0 S54=3 S55 - 0 3 0 S55=0 S58 - 2 2 3 S58=2 S64 - - 1 0 S64=1 S66 1 0 - 0 S66=0 S68 - 255 3 255 S68=255 S92 1 1 - 0 S92=1 S110 - 255 - 255 S110=255 S111 - 255 30 255 S111=30 S130 1 - 2 2 S130=2 S131 1 - 2 2 S131=2 With some settings we have been able to connect to csn T2500s at 19,200 via cu, but the same settings cause the dialTBIT to abort when it runs against our T2500 . So what do we do to cut through this Gordian Knot? -------------------------------------------- jonr%bigsky@csn.org dave%oldcolo@csn.org