Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.1 6/24/83; site mgweed.UUCP Path: utzoo!linus!philabs!seismo!harpo!eagle!mhuxl!houxm!ihnp4!we13!mgweed!rjr From: rjr@mgweed.UUCP Newsgroups: net.ham-radio Subject: Dentron power supply comment Message-ID: <4749@mgweed.UUCP> Date: Fri, 18-Nov-83 16:38:20 EST Article-I.D.: mgweed.4749 Posted: Fri Nov 18 16:38:20 1983 Date-Received: Sun, 20-Nov-83 00:07:32 EST Organization: AT&T Western Electric - Montgomery Illinois Lines: 16 I just purchased the Dentron power supply listed in the new AES catalog. This is the supply that was used to power the Dentron transciever. It was a $129 unit now being sold for $39. The specs are not too clear in the ad. The regulated output is only good for 2 amps. The high current output is unregulated and puts out 17.5 volts unloaded and drops to about 13 or so with a 16 amp load. The transformer is supposed to be rated for 20 amps. Unfortunately, there is little room to add heat sinks large enough to permit regularing the high current output without mounting them on top of the cabinet. I guess it is still worth the sale price, but not what I expected. Bob, K9EUI