Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!linus!security!genrad!decvax!ittvax!ittral!shacklet From: shacklet@ittral.UUCP (Captain Electron) Newsgroups: net.auto Subject: Re: Electrical ? Problem Message-ID: <326@ittral.UUCP> Date: Thu, 15-Dec-83 10:23:20 EST Article-I.D.: ittral.326 Posted: Thu Dec 15 10:23:20 1983 Date-Received: Sat, 17-Dec-83 01:08:56 EST References: GLOBE.116 Lines: 6 I had a 74 Lemans with the same problem. It turned out to be a fuse located on a line coming from the alternator. If that's not it check the motor speed selector resistors located in the heater box. They are accessable by removing a small plate on top of the box under the hood. There is also a large diode on the same assembly; sometimes that opens or shorts and causes weird problems.(the diode looks like the kind in the alternator).