Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!linus!vaxine!wjh12!genrad!decvax!mcnc!ecsvax!mjg From: mjg@ecsvax.UUCP Newsgroups: micro.general,micro.ibm,net.micro,net.micro.pc,net.dcom Subject: Re: Datec to IBM problems Message-ID: <2234@ecsvax.UUCP> Date: Mon, 2-Apr-84 14:42:26 EST Article-I.D.: ecsvax.2234 Posted: Mon Apr 2 14:42:26 1984 Date-Received: Wed, 4-Apr-84 07:47:58 EST References: ecsvax.2220 Lines: 13 I have had trouble with Datec 212 modems also. In my case, however the problem was the reverse i.e. it would work at home and not in the office because the office uses a PABX which expects a very short loop to the phone and consequently will not recognize off hook. I found I had to manually take the phone of hook to draw enough current to trip the pabx before dialling. A second problem is that the modem will not dial if it does not see the correct RS232 status line - I think it is DTR - data terminal ready. Check the lights on the front. When you power up, before dialling you should see the TR light\ on, if you don't then it won't originate a call. Mike Gingell decvax!mcnc!ecsvax!mjg