Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.2 9/18/84; site brl-tgr.ARPA Path: utzoo!linus!philabs!cmcl2!seismo!brl-tgr!internet!Eaton@HI-MULTICS.ARPA From: Eaton@HI-MULTICS.ARPA Newsgroups: net.micro.cpm Subject: RE: IEEE-488/CENTRONICS on OSBORNE Message-ID: <6021@brl-tgr.ARPA> Date: Thu, 22-Nov-84 04:53:31 EST Article-I.D.: brl-tgr.6021 Posted: Thu Nov 22 04:53:31 1984 Date-Received: Sat, 24-Nov-84 01:55:32 EST Sender: news@brl-tgr.ARPA Organization: Ballistic Research Lab Lines: 28 Ron, the following diagram should allow you to connect the OSBORNE EXECUTIVE'S IEEE-488 port to a CENTRONICS port: IEEE-488 CENTRONICS 1 ------- DATA0 (LSB) -----> 2 2 ------- DATA1 -----------> 3 3 ------- DATA2 -----------> 4 4 ------- DATA3 -----------> 5 13 ------- DATA4 -----------> 6 14 ------- DATA5 -----------> 7 15 ------- DATA6 (MSB)------> 8 16 ------- DATA7 (PAR) -----> 9 6 ------- STROBE* ---------> 1 12 ------- GROUND ----------> 19 8 <------ BUSY ------------- 11 NOTE: STROBE IS NORMALLY NEGATIVE GOING PULSE. BUSY LINE IS HIGH WHEN PRINTER IS BUSY. THERE ARE PULLUP RESISTORS ON THE IEEE-488 WHICH PULL THIS LINE HIGH IF THE CABLE IS UNPLUGGED OR IS WIRED INCORRECTLY. GOOD LUCK AND LET ME KNOW HOW IT TURNS OUT. I STILL HAVE TO REWIRE MY CABLE AS I TOO USED THE DIAGRAM ON PAGE 445 IN THE SYSTEM REFERENCE MANUAL. WE "BOTH" KNOW THAT IS OUT TO LUNCH. Jesse (all for better, more correctter documintasion) Eaton.HFED@HI-MULTICS