Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.3 4.3bsd-beta 6/6/85; site ucbvax.ARPA Path: utzoo!watmath!clyde!burl!ulysses!ucbvax!info-vax From: info-vax@ucbvax.ARPA Newsgroups: fa.info-vax Subject: Reply to: VMS monitoring program from DECUS Message-ID: <9286@ucbvax.ARPA> Date: Tue, 23-Jul-85 19:51:01 EDT Article-I.D.: ucbvax.9286 Posted: Tue Jul 23 19:51:01 1985 Date-Received: Thu, 25-Jul-85 07:17:56 EDT Sender: daemon@ucbvax.ARPA Organization: University of California at Berkeley Lines: 11 From: <#D14%DDATHD21.BITNET@WISCVM.ARPA> Dear Peter, there are some new symbols. F.e. instead of PMS$GL_DEQ there are PMS$GL_DEQ_LOC, PMS$GL_DEQ_IN and PMS$GL_DEQ_OUT. The ..._IN and ..._OUT counters are zero at our VAX. So I think you should change the source from PMS$GL_DEQ to PMS$GL_DEQ_LOC etc. Reinhard Goeth @ Technical University Darmstadt, W.Germany, Europe (Beware of the number-sign. It's part of my userid !!!)