Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.1 6/24/83; site utah-cs.UUCP Path: utzoo!linus!philabs!cmcl2!seismo!utah-cs!b-davis From: b-davis@utah-cs.UUCP (Brad Davis) Newsgroups: net.micro.pc Subject: Re: IBM AT Serial Line Pinouts Message-ID: <3456@utah-cs.UUCP> Date: Wed, 28-Aug-85 18:30:30 EDT Article-I.D.: utah-cs.3456 Posted: Wed Aug 28 18:30:30 1985 Date-Received: Thu, 29-Aug-85 08:44:14 EDT References: <2077@ukma.UUCP> <311@ecsvax.UUCP> Reply-To: b-davis@utah-cs.UUCP (Brad Davis) Organization: University of Utah VCIS Group Lines: 24 [] There was one missing connection. This list was verified from the AT Tech Ref manual. >DB-25 PC-AT Signal source Purpose >----- ----- -------------- -------- > 1 - -- Protective ground (unconnected) > 2 3 PC Send data > 3 2 Modem Receive data > 4 7 PC Request to send > 5 8 Modem Clear to send > 6 6 Modem Data set ready > 7 5 -- Signal ground > 8 1 Modem Carrier detect > 20 4 PC Data terminal ready * 22 9 Modem Ring Indicator -- Brad Davis {ihnp4, decvax, seismo}!utah-cs!b-davis b-davis@utah-cs.ARPA