Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.1 6/24/83; site sphinx.UChicago.UUCP Path: utzoo!watmath!clyde!cbosgd!ihnp4!gargoyle!sphinx!ronr From: ronr@sphinx.UChicago.UUCP (Ron Rusnak) Newsgroups: net.lan Subject: Codenoll 2020 to 3Com 3C400 Multibus problem Message-ID: <1156@sphinx.UChicago.UUCP> Date: Tue, 1-Oct-85 19:45:44 EDT Article-I.D.: sphinx.1156 Posted: Tue Oct 1 19:45:44 1985 Date-Received: Thu, 3-Oct-85 04:23:29 EDT Organization: U. Chicago - Computation Center Lines: 17 We have built several ethernet gateways using 68000 multibus and 3com multibus ethernet controllers. They work quite well when connected to coax transceivers. We are now trying to connect them to Codenoll 2020 fiber optic transceivers. The result is that the 3Com board's throughput drops by a factor of six. Both the 3com controllers and the Codenoll transceivers claim to meet Ethernet 1.0 specifications. Has anyone out there run into a similar problem or does anyone have any advice on how to get around the problem? Ron Rusnak (...!ihpn4!gargoyle!sphinx!ronr) University of Chicago Computation Center Brought to you by Super Global Mega Corp .com