Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.2 9/18/84; site ecsvax.UUCP Path: utzoo!linus!decvax!mcnc!ecsvax!phco From: phco@ecsvax.UUCP (John Miller) Newsgroups: net.decus Subject: Re: TSX-Plus/RT-11 Help Wanted Message-ID: <538@ecsvax.UUCP> Date: Sun, 6-Oct-85 17:38:58 EDT Article-I.D.: ecsvax.538 Posted: Sun Oct 6 17:38:58 1985 Date-Received: Wed, 9-Oct-85 03:40:14 EDT References: <12035@rochester.UUCP> Reply-To: phco@ecsvax.UUCP (John Miller) Organization: Univ. of North Carolina at Chapel Hill Lines: 17 All he needs to do is to modify TSGEN.MAC (between the "======"'s that mark the user-configurable parameters. RT-11 multiterminal support is NOT required. If he has any difficulty bringing TSX+ up after the regeneration, he might need to reduce the size of RT-11 by regenerating the RT-11 baseline or single job monitor, but that's unlikely. Also, if the system seems to crash frequently with a "no free fork blocks" message, he may need to increase NUMFRK (near the beginning of TSGEN.MAC). With the RT-11 baseline monitor, 14 lines running on two DZ-11 multiplexors, and NUMFRK = 170, we have few problems on an 11/24. -- John Miller (ecsvax!phco) Dept. of Pharmacology, Univ. of N.C.-Chapel Hill Chapel Hill, NC 27514 (919) 966-4628