Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.3 4.3bsd-beta 6/6/85; site ucbvax.BERKELEY.EDU Path: utzoo!decvax!decwrl!ucbvax!info-vax From: Provan@LLL-MFE.ARPA Newsgroups: mod.computers.vax Subject: answer to my Decnet problem Message-ID: <8512200742.AA11816@ucbvax.berkeley.edu> Date: Thu, 19-Dec-85 11:53:00 EST Article-I.D.: ucbvax.8512200742.AA11816 Posted: Thu Dec 19 11:53:00 1985 Date-Received: Sat, 21-Dec-85 00:19:56 EST Sender: daemon@ucbvax.BERKELEY.EDU Organization: The ARPA Internet Lines: 9 Approved: info-vax@sri-kl.arpa someone suggested i run StartNet with verify on, which was quite illuminating. i was under the impression that the volatile database was initialized from the permanent database by magic; i wasn't aware that StartNet just issues various Set commands to do the job. in my case, there was an empty StartPSI.Com in Sys$Manager:, so StartNet called it to configure the lines and circuits rather than trusting the permanent database. thanks to all who tried to help. now if i could just figure out where that StartPSI.Com came from....