Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.2 9/18/84; site tikal.UUCP Path: utzoo!utcsri!ubc-vision!uw-beaver!tikal!stan From: stan@tikal.UUCP (Stan Tazuma) Newsgroups: net.unix-wizards,net.bugs.4bsd Subject: UDA50 problems Message-ID: <296@tikal.UUCP> Date: Mon, 16-Dec-85 11:58:16 EST Article-I.D.: tikal.296 Posted: Mon Dec 16 11:58:16 1985 Date-Received: Tue, 17-Dec-85 07:22:05 EST Distribution: net Organization: Teltone Corp., Kirkland, WA Lines: 36 Configuration: VAX 11/750 4.1bsd Unix 1 UDA50 disk controller, 2 RA81's TU78 tape controller with 2 slaves Problem messages: uda0: soft error, disk transfer error, unit 1 uda0: soft error, SDI error, unit 1, event 0353 uda0: soft error, disk transfer error, unit 0 uda0: soft error, SDI error, unit 0, event 0353 The SDI error message is always paired with the disk transfer error message. Notice no sector numbers. The messages occur sometimes 3 hours apart, sometimes 24 hours apart, but usually not in bunches. Typically, only 2-6 occur per day on a fairly active system. Other: Out of 3 identical installations, we get these error messages on only one. The system doesn't crash when these messages occur, but peculiar things happen (like the autoboot sequence pausing (until a key is hit) just before /etc/rc is run (no, we don't have rc prompt for anything)). Anybody have experiences with these errors? We have had DEC field service on this for weeks (months?), and they don't seem to know what to do. We have no manuals on the UDA50 (the computers are installed at customer sites), so if anybody out there does, maybe telling us what event 0353 is would be of some help(?) Thanks in advance.