Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.3 4.3bsd-beta 6/6/85; site ucbvax.BERKELEY.EDU Path: utzoo!decvax!bellcore!ulysses!ucbvax!info-vax From: A105@UWOCC1.BITNET (Brent Sterner) Newsgroups: mod.computers.vax Subject: DMF-32 parallel port printer **SOLVED** Message-ID: <8601230939.AA23206@ucbvax.berkeley.edu> Date: Fri, 17-Jan-86 12:50:00 EST Article-I.D.: ucbvax.8601230939.AA23206 Posted: Fri Jan 17 12:50:00 1986 Date-Received: Fri, 24-Jan-86 03:14:55 EST Sender: daemon@ucbvax.BERKELEY.EDU Organization: The ARPA Internet Lines: 19 Approved: info-vax@sri-kl.arpa Bingo. There is a DMF-32 h/w book. The last appendix says the strobe pin out for the parallel interface is pin 37. Our local h/w guy went fishing and found it to be pin 8. A jumper proved the scope was right; data came forth like a gentle spring rain. Once the cable is fixed we will have a real printer! Since no one has replied to my original query, I can't thank anyone. Maybe this information will be useful to other sites, however. Maybe DEC will get the documentation fixed as well. I have informed TSC of the documentation error. Hope it propagates to the right places. Brent Sterner Computing & Communications Services Natural Sciences Building The University of Western Ontario London, Ontario, Canada N6A 5B7 Telephone (519)679-2151 (secretary) 2167 (direct)