Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.3 4.3bsd-beta 6/6/85; site ucbvax.berkeley.edu.BERKELEY.EDU Path: utzoo!watmath!clyde!burl!ulysses!bellcore!decvax!decwrl!ucbvax.berkeley.edu!info-vax From: garry@LASSPVAX.TN.CORNELL.EDU (Garry Wiegand) Newsgroups: mod.computers.vax Subject: Re: Aynchronous decnet troubles Message-ID: <8601242318.AA04535@lasspvax.tn.cornell.edu> Date: Fri, 24-Jan-86 18:18:49 EST Article-I.D.: lasspvax.8601242318.AA04535 Posted: Fri Jan 24 18:18:49 1986 Date-Received: Sun, 26-Jan-86 17:14:16 EST References: <8601170721.AA28452@vax135.UUCP> Sender: daemon@ucbvax.berkeley.edu.BERKELEY.EDU Organization: Cornell Engineering && Flying Moose Graphics Lines: 14 Approved: info-vax@sri-kl.arpa Just a quick note: we also had trouble getting asynchrounous decnet (decnet through a terminal line) up and running. Ours had multiplexers and leased phone lines in the way to make it more interesting. What finally made it "come alive" was switching the vax/750 end of the wire from a DZ-11 port (TTxx) to a DMF port (TXxx). After a period of confusion, you may also have to SET TERM/PROTO=NONE and SET HOST/DTE link-line: on both ends to let the bytes flush out. garry wiegand garry@batcomputer.tn.cornell.edu PS - DEC should consider building error messages into DECnet someday :-)