Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.2 9/5/84; site mmm.UUCP Path: utzoo!watmath!clyde!cbosgd!ihnp4!stolaf!mmm!leon From: leon@mmm.UUCP (Leon Schilmoeller) Newsgroups: net.unix-wizards Subject: Re: disk system hangs on a VAX-750 with SI controller. Message-ID: <512@mmm.UUCP> Date: Mon, 17-Feb-86 09:49:15 EST Article-I.D.: mmm.512 Posted: Mon Feb 17 09:49:15 1986 Date-Received: Tue, 18-Feb-86 04:04:28 EST References: <136@uwslh.UUCP> Distribution: net Organization: 3M Company, St. Paul, Minn. Lines: 44 > We have a problem with our disk system hanging and need help. > We are running a VAX-11/750 with 4.2BSD unix. > The disk system is a Systems Industries 9900 controller with a Fujitsu > eagle disk drive and two CDC 9730-80 disk drives (a sealed 67 M drive). > The controller emulates a massbus device and we use the hp device driver > that came with 4.2BSD. > Occasionally (usually about once a month but last week as much as 5 times > per day) the computer will hang as though a task completion interrupt from > the disk had been lost. Pressing the reset switch on the controller will > cause the system to pick up running as though nothing had happened. > Another site near us also has seen this problem. We just installed > a new power supply and the latest firmware in the controller, but it did > not help. SI suggested using their version of the hp driver, but > (a) did not think it would help and (b) I don't see anything in their changes > that appears to address this problem. > Does anyone know what is going on and what we can do about the problem? > 1. Is it hardware (and if so has anyone identified it well enough for > SI to fix it)? > 2. Is it software and if so can someone point me to a fix. > 3. I have considered going into the hp driver and modifying it so that > there is a timeout on pending disk activity (or maybe use the system > lightning bolt) so that if we wait over one second for a disk interrupt > we will consider the disk drive to be hung and issue a reset. > Has anyone tried this and will you send me the code if you have. > Or when it hangs does the controller become so stuck that a software > issued reset is ignored and we have to hit the switch. > Any help on this will be appreciated. > -- > David E. Miran ...!{seismo,harvard,topaz,ihnp4}!uwvax!uwslh!dem > Wisconsin State Hygiene Lab (608) 262-0019 > University of Wisconsin > 465 Henry Mall > Madison, WI 53706 We have experienced the same problem with the si9900 on a VAX 11/780. We have 3 eagles and a 9766 on the one controller. Using the hp driver from SI does not make any difference, at least not for us. It has been some time since a reset has been needed on my system, but as you have indicated, there appears to be no real pattern. Sorry I do not have a fix, but just wanted to let you know it is not only a 750 problem. Leon Schilmoeller ihnp4!mmm!leon 3M 612-736-9653 St. Paul, MN 55144