Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!watmath!clyde!burl!ulysses!mhuxr!mhuxt!houxm!whuxl!whuxlm!akgua!gatech!seismo!brl-adm!brl-smoke!smoke!JBS%DEEP-THOUGHT@mit-eddie.arpa From: JBS%DEEP-THOUGHT@mit-eddie.arpa Newsgroups: net.unix-wizards Subject: dz-11 on a VAX-11/750 at 19,200 baud. Message-ID: <1577@brl-smoke.ARPA> Date: Thu, 6-Mar-86 02:07:55 EST Article-I.D.: brl-smok.1577 Posted: Thu Mar 6 02:07:55 1986 Date-Received: Sun, 9-Mar-86 08:41:26 EST Sender: news@brl-smoke.ARPA Lines: 17 I have been experimenting with running a vt220 here at 19.2Kbaud. The terminal works great except when sending more that about two pages without a pause--at that rate, the terminal can't quite keep up and loses a little data. The lost data is not really my problem though. What I'm worried about is that on the console, the system spits out occasional "dz0,4: silo overflow." Does anyone know what is wrong, and if so, what I can do to fix it? (oh, did I forget to mention that it is running 4.3BSD?) Jeff Siegal -------