Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!watmath!clyde!burl!ulysses!allegra!princeton!orsvax1!pyrnj!caip!seismo!brl-adm!brl-smoke!smoke!LMTRA@sri-kl.arpa From: LMTRA@sri-kl.arpa Newsgroups: net.micro Subject: Multiplan portability Message-ID: <2077@brl-smoke.ARPA> Date: Tue, 25-Mar-86 11:47:57 EST Article-I.D.: brl-smok.2077 Posted: Tue Mar 25 11:47:57 1986 Date-Received: Thu, 27-Mar-86 01:09:23 EST Sender: news@brl-smoke.ARPA Lines: 16 In response to Steve Westfall's query and anyone else who is interested: Multiplan has a symbolic interchange format called "SYLK" that assures portability **between compatible versions of the software (usually same release level or upward)**. To use it, you select T(ransfer) O(ptions) S(ymbolic) before you save. Before reloading on the other machine, again do T(ransfer) O(ptions) S(ymbolic), then T(ransfer) L(oad). This should properly load the sheet, but it will be a slow process. To restore efficiency, save it on this second machine under T(ransfer) O(ptions) N(ormal). I have used SYLK successfully for machine interchange (between CP/M and MS-DOS) and for generating spreadsheets from programming languages. Good luck Leon Traister (LMTRA@SRI-KL.Arpa) -------