Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.3 4.3bsd-beta 6/6/85; site ucbvax.BERKELEY.EDU Path: utzoo!watmath!clyde!burl!ulysses!bellcore!decvax!ittatc!dcdwest!sdcsvax!ucbvax!mitre-bedford.arpa!jhs From: jhs@MITRE-BEDFORD.ARPA Newsgroups: net.micro.atari8 Subject: Re: Using NTSC computers Down Under?? Message-ID: <8604012338.AA08887@mitre-bedford.ARPA> Date: Tue, 1-Apr-86 19:00:57 EST Article-I.D.: mitre-be.8604012338.AA08887 Posted: Tue Apr 1 19:00:57 1986 Date-Received: Sat, 5-Apr-86 08:42:27 EST References: <995@eagle.ukc.ac.uk> Sender: daemon@ucbvax.BERKELEY.EDU Organization: The MITRE Corp., Bedford, MA Lines: 8 Power transformers designed for 60 Hz power may overheat when run on 50 Hz because they don't have enough iron in them and their "leakage inductance" isn't high enough. This might account for a power supply failure, especially if the manufacturer was trying to cut costs in the transformer department. -John Sangster jhs@mitre-bedford.arpa ...ihnp4!linus!mbunix!jhs