Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10 5/3/83 based; site homxb.UUCP Path: utzoo!watmath!clyde!burl!ulysses!allegra!whuxlm!whuxl!houxm!homxb!gemini From: gemini@homxb.UUCP (Rick Richardson) Newsgroups: net.micro.att Subject: Re: Unix PC communications trouble Message-ID: <1377@homxb.UUCP> Date: Wed, 2-Apr-86 08:31:08 EST Article-I.D.: homxb.1377 Posted: Wed Apr 2 08:31:08 1986 Date-Received: Sat, 5-Apr-86 06:34:53 EST References: <423@mhuxi.UUCP> Organization: PC Research, Inc. Lines: 16 I have had the same trouble (characters echoed are the ones that were typed many characters before), on my 7300 which has 3 serial ports. The way I used it, all 3 serial ports were running a very basic terminal emulator to talk 9600 baud to 1) a development system, plus 2) a "product" dumping data at 9600 baud using XON/XOFF flow control, and 3) another one like 2). No remote logins. Under this heavy load, the 7300 flow controlled 2) and 3) alternately for awhile, then finally got so confused that my session on 1) started getting the delayed by characters echo problem. Once this happened, I had to reboot to fix. I have since given up trying to use the 7300 as a replacement for three terminals in the lab. Rick Richardson, PC Research, Inc. (201) 922-1134 ..!ihnp4!houxm!castor!{rer,pcrat!rer} <--Replies to here, not to homxb!!!