Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.3 4.3bsd-beta 6/6/85; site ucbvax.BERKELEY.EDU Path: utzoo!decvax!bellcore!ulysses!UCBVAX.BERKELEY.EDU!kube%cogsci From: kube%cogsci@UCBVAX.BERKELEY.EDU (Paul Kube) Newsgroups: mod.ai Subject: correction to response to Nevin, AIList V4 #120 Message-ID: <8605172253.AA05508@cogsci.Berkeley.EDU> Date: Sat, 17-May-86 18:53:31 EDT Article-I.D.: cogsci.8605172253.AA05508 Posted: Sat May 17 18:53:31 1986 Date-Received: Thu, 22-May-86 01:11:57 EDT Sender: daemon@ucbvax.BERKELEY.EDU Organization: The ARPA Internet Lines: 20 Approved: ailist@sri-ai.arpa Instead of Since the standard deviation of the difference of two identically normally distributed random variables is twice the standard deviation of either variable, the temporal disparity measurement has 95% confidence interval of 4*10^-6 seconds. I should have said Since the standard deviation of the difference of two identically normally distributed random variables is less than twice the standard deviation of either variable, the temporal disparity measurement has 95% confidence interval of less than 4*10^-6 seconds. The argument for getting to 4*10^-7 second accuracy still holds. Paul Kube Berkeley EECS kube@berkeley.edu