Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!decvax!decwrl!ucbvax!UTAH-CS.ARPA!cetron%utah-cbd From: cetron%utah-cbd@UTAH-CS.ARPA.UUCP Newsgroups: mod.computers.vax Subject: microVMS 4.4, DECnet 4.4 and DEQNA's Message-ID: <8606101651.AA18211@utah-cbd.ARPA> Date: Tue, 10-Jun-86 12:51:28 EDT Article-I.D.: utah-cbd.8606101651.AA18211 Posted: Tue Jun 10 12:51:28 1986 Date-Received: Wed, 11-Jun-86 19:04:07 EDT Sender: daemon@ucbvax.BERKELEY.EDU Organization: The ARPA Internet Lines: 31 Approved: info-vax@sri-kl.arpa I recently brought up uVMS 4.4 with no apparent trouble on my MVII. All seems well except the DECnet keeps going up and down every 7-12 minutes....messages like: DECnet event 4.7, circuit down, circuit fault ... Circuit QNA-0, Line synchronization lost DECnet event 4.10, circuit up ... Circuit QNA-0 and this repeats roughly 4-6 times and then stays up for 7-12 minutes.... over the weekend I produced 120 pages of OPCOM messages....I have since turned off monitor logging of events 4.7 and 4.10 and the system seems more robust (it stays up 10-15 minutes now).... The afflicted MVII connects into a DELNI with another MVII running 4.2, an 11/44 running RSX-11M+ DECnet, an 11/73 MINC running RSX-11M+ DECnet as well as a 750 and an HP bobcat running TCP/IP. Then DELNI then connects into a larger TCP/IP speaking ethernet... None of the UNIBUS machines show any line synchronization problems. The 11/73 MINC (with a DEQNA) shows no problems. The other MVII running uVMS 4.2 shows roughly 2-4 cycles per day of this same pattern. Has anyone else noticed this problem? Is it hardware? or the new 4.4? -ed cetron%utah-cbd@utah-cs.arpa