Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!watmath!clyde!caip!topaz!nike!think!husc6!harvard!hscfvax!pavlov From: pavlov@hscfvax.UUCP (840033@G.Pavlov) Newsgroups: net.unix-wizards Subject: Re: getty speed switching under Ultrix v1.2 Message-ID: <210@hscfvax.UUCP> Date: Sat, 16-Aug-86 03:29:10 EDT Article-I.D.: hscfvax.210 Posted: Sat Aug 16 03:29:10 1986 Date-Received: Sun, 17-Aug-86 10:34:37 EDT References: <2996@brl-smoke.ARPA> Organization: Health Sciences Computing Facility, Harvard University Lines: 12 In article <2996@brl-smoke.ARPA>, iglesias@ICS.UCI.EDU (Mike Iglesias) writes: > I've set up /etc/gettytab on our Microvax II running Ultrix v1.2 to > switch line speeds on breaks. However, it doesn't seem to be very > reliable. It appears that Ultrix is seeing one break as several, so > it skips past the correct speed about half the time. ....... Well, this probably shouldn't have anything to do with it, but including "fd#5" (or 2,3,4,whatever) in the default section of gettytab cleared up similar break recognition/speed switch problems for us (on uVax II's). greg pavlov, fstrf, amherst, ny.