Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!mnetor!seismo!lll-crg!lll-lcc!qantel!ihnp4!iham1!ejk47 From: ejk47@iham1.UUCP (kufeldt) Newsgroups: net.micro.att Subject: Help 6300+ and Penril ACU Message-ID: <558@iham1.UUCP> Date: Thu, 25-Sep-86 09:37:41 EDT Article-I.D.: iham1.558 Posted: Thu Sep 25 09:37:41 1986 Date-Received: Fri, 26-Sep-86 01:56:50 EDT Organization: AT&T Bell Labs, Naperville, IL Lines: 36 Keywords: 6300+, Penril ACU I need help connecting a Penril ACU to a AT&T 6300+. The ACU works fine for processes that use getty (like ct), but does not work for processes that use uugetty (like cu). When I try to use cu the response is DEVICE LOCKED. I loooked at files Device and Dialers. Those files appear correct. (I compared them against a Penril ACU defined on a 3B2.) Called Customer Support and they said check the cable between the 6300 and the ACU. I did and did not spot anything obvious. The cable is wired like the following: 6300+ Penril Pin to Pin 1 1 2 2 3 3 6 6 7 7 8 8 20 20 22 22 The above wiring worked fine on the 3B2, but does not on the 6300+. As soon as the CU command is invoked, I get a DEVICE LOCKED response. Note, there are no entries in the /usr/spool/locks directory when this happens. The response appears to be generated by what the 8250 chip is seeing on a status? lead. I would sure appreciate any help I can get. Ed Kufeldt AT&T N.S. E. Mail: iham1!ejk47 Work Phone: (312) 510-2516