Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!mnetor!seismo!lll-crg!ames!scubed!piaget!jc From: jc@piaget.UUCP (John Cornelius) Newsgroups: comp.dcom.lans Subject: Re: connecting thin ethernet stations to a thick cable Message-ID: <115@piaget.UUCP> Date: Thu, 4-Dec-86 23:48:28 EST Article-I.D.: piaget.115 Posted: Thu Dec 4 23:48:28 1986 Date-Received: Fri, 5-Dec-86 21:15:57 EST References: <1097@uqcspe.OZ> <157@pta.OZ> <447@yetti.UUCP> Reply-To: jc@piaget.UUCP (John Cornelius, System Guru) Organization: International Widget Lines: 10 If the characteristic impedances of the two cables are identical and the BNC/N adapter does not introduce a lump impedance different than the characteristic impedance, the simple transition connector will work. I note that BNC hardware comes in 50 ohm and 75 ohm characteristic impedances. -- John Cornelius (...!sdcsvax!piaget!jc)