Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!mnetor!seismo!rutgers!mit-eddie!genrad!decvax!mcnc!godot!sherouse From: sherouse@godot.UUCP (George W. Sherouse) Newsgroups: comp.periphs Subject: Re: Has anyone experienced Super-Eagle (Fujitsu M2361) problems? Message-ID: <714@godot.UUCP> Date: Sat, 6-Dec-86 16:43:28 EST Article-I.D.: godot.714 Posted: Sat Dec 6 16:43:28 1986 Date-Received: Sun, 7-Dec-86 05:26:52 EST References: <4063@utah-cs.UUCP> Reply-To: sherouse@godot.UUCP (George W. Sherouse) Organization: Radiation Oncology, NCMH/UNC, Chapel Hill Lines: 19 We have been running two SI9761 drives with their wonderful cache controller for about a year. We love them to pieces and have experienced only one major problem. About the time the warranty ran out, one of the drives started popping up with spontaneous bad blocks all over. I believe this was in the spring :-) It took SI a while to sort out the cause of the problem - the drive, the cache controller, and the CMI interface were all covering for one another. Eventually, the process of elimination brought us to the point of replacing the HDA. It turned out that this same thing was going on at several other sites at more or less the same time - and all with HDAs from the same batch. We have had no problems since the HDA was replaced. BTW, we have borrowed a performance monitor for the cache controller this week and were pleased to find that our average hit rate is around 55% and our average request service time is running around 15 ms. You should see what happens during the boot fsck runs!!! - George